1.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145466

ABSTRACT

Objectives: With regard to the prevalence of abutment screw loosening (SL) and bone height reduction, particularly in the posterior regions of the jaws, as well as the contradictory issue of applying short implants instead of surgeries, along with all preparations associated with longer implants, the present study aimed to compare the amount of torque loss in short implants with increased vertical cantilever abutments and standard ones. Material and Methods: In this experimental study, a total number of 20 implants (MegaGen Implant Co., Ltd, South Korea) with 4.5 mm diameter including 10 short implants (7 mm) and 10 standard ones (10 mm) were utilized. Using a surveyor, fixtures were perpendicularly mounted in 13×34 mm resin for short implants and 19×34 mm resin for standard ones. The abutments of the same height but different cuff heights (2.5 mm for the standard implants and 5.5 mm for the short ones) were then tightened with 30 N.cm, via a digital torque meter. To compensate the settling effect, the abutment screw was re-tightened with 30 N.cm after 10 min. Upon applying 500,000 cycles at 75 N.cm and 1 Hz along the longitudinal axis on each sample, blind reverse torque value (RTV) was measured with a digital torque meter. The data were finally analyzed using Student's t-test. Results:Both groups experienced torque loss, but there was no statistically significant difference between the case and control groups in terms of abutment SL (p = 0451). Conclusion: Short implants seem to be a good mechanical alternative in emergencies with respect to torque loss and abutment SL. (AU)


Objetivos: Considerando a prevalência de afrouxamento de parafuso dos pilares, redução da altura óssea especialmente nas regiões posteriores, a questão contraditória da aplicação de implantes curtos em vez de cirurgias e todos os preparos associados a implantes mais longos, este estudo buscou comparar implantes curtos com pilares cantilever verticais aumentados e implantes padrão na quantidade de perda de torque. Material e métodos: Neste estudo experimental, foram utilizados 20 implantes (Megagen, Coreia do Sul) com diâmetro de 4,5 mm, incluindo 10 implantes curtos (7 mm) e 10 implantes padrão (10 mm). A fixação foi realizada perpendicularmente em uma resina 13 × 34 mm para implantes curtos e uma resina 19 × 34 mm para implantes padrão, usando um topógrafo. Os pilares da mesma altura, mas com diferentes comprimentos de manguito (2,5 mm para os implantes padrão e 5,5 mm para os implantes curtos) foram apertados com 30 N, utilizando um torquímetro digital. Para compensar o efeito de sedimentação, o parafuso do pilar foi reapertado com 30 N após 10 min. Depois de aplicar 500.000 ciclos a 75 N e 1 Hz ao longo do eixo longitudinal em cada amostra, o valor de torque reverso cego foi medido com um medidor de torque digital. Os dados foram analisados pelo teste t de Student. Resultados: Todos os grupos tiveram perda de torque, mas não houve diferença estatisticamente significativa entre os grupos caso e controle em termos de afrouxamento do parafuso do pilar (p = 0451). Conclusão: Os implantes curtos parecem ser uma boa alternativa mecânica em emergências em termos de perda de torque e afrouxamento do parafuso do pilar. (AU)


Subject(s)
Bone Screws , Torque , Dental Implantation
2.
Ciênc. rural (Online) ; 50(5): e20190764, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1133252

ABSTRACT

ABSTRACT: Vertical screw conveyors have low energy efficiency but this is generally acceptable within the normally low power range. Previously, a fuzzy logic approach was used to model volumetric efficiency and specific energy consumption in screw conveyors. The performance of conveyors in different working conditions and the geometry of the screw were studied. It was reported that increasing the screw speed, pitch, and loading angle also increases specific energy consumption. In this study, an intelligent fuzzy model based on the Mamdani approach was developed to predict volumetric efficiency and specific energy consumption. The model inputs included the slope, speed, and pitch of screw conveyors. The fuzzy model consists of 27 rules in which three parameters, namely the goodness of fit (η), relative error (ε), and coefficient of correlation (R), are used to evaluate the model. The goodness of fit, relative error, and coefficient of correlation values were 0.986, 5.28%, and 0.99, respectively, for volumetric efficiency and 0.987, 4.93%, and 0.99, respectively, for specific energy consumption. Results revealed that the developed model is capable of predicting volumetric efficiency and specific energy consumption in barley transport under different working conditions with high accuracy.


RESUMO: Os transportadores de parafuso verticais têm baixa eficiência energética, mas isso geralmente é aceitável dentro da faixa de potência normalmente baixa. Anteriormente, uma abordagem lógica fuzzy era usada para modelar a eficiência volumétrica e o consumo específico de energia em transportadores de parafuso. O desempenho dos transportadores em diferentes condições de trabalho e a geometria do parafuso foram estudados. Verificou-se que aumentar a velocidade do parafuso, a inclinação e o ângulo de carga também aumenta o consumo de energia específico. Neste estudo, um modelo fuzzy inteligente baseado na abordagem de Mamdani é desenvolvido para prever a eficiência volumétrica e o consumo específico de energia. As entradas do modelo incluem a inclinação, velocidade e inclinação dos transportadores de parafuso. O modelo fuzzy consiste em 27 regras, nas quais três parâmetros, a saber, qualidade do ajuste (η), erro relativo (ε) e coeficiente de correlação (R), são usados para avaliar o modelo. Os valores de ajuste, erro relativo e coeficiente de correlação são de 0,986, 5,28% e 0,99, respectivamente, para eficiência volumétrica e 0,987, 4,93% e 0,99, respectivamente, para consumo específico de energia. Os resultados revelam que o modelo desenvolvido é capaz de prever eficiência volumétrica e consumo específico de energia no transporte de cevada sob diferentes condições de trabalho com alta precisão.

3.
Braz. dent. sci ; 23(3): 1-9, 2020. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1117433

ABSTRACT

A 22 year old male patient reported to the hospital with a chief complaint of forwardly placed teeth. On examination patient had Angle's Class I malocclusion and proclination of the anterior teeth. There were signs of frictional keratosis on the buccal mucosa. Treatment plan was to extract the third molars alone and distalize the entire maxillary arch with palatal mini-implants. 0.022 MBT brackets were bonded on the buccal aspect. 0.019" x 0.025" stainless steel wire was placed sequentially. Mini-implants were placed on the posterior alveolus on the palatal surface of maxilla. Retractive force was applied from an attachment bonded on the palatal aspect of the maxillary canine. Patient was reviewed periodically. Comparison of pre-treatment and post-treatment results revealed that the entire maxillary arch intruded and translated distally with a counter-clockwise rotation of the mandible with reduction in LAFH. There was a mild reduction in inter-canine with marginal expansion in the premolar and molar region. An improvement in facial profile was noted with no sign of root resorption. Thus, the posterior alveolus may be considered as a new and appropriate site for placement of mini-implant to bring about distal movement of the entire maxillary dentition (AU)


Um Paciente do sexo masculino, 22 anos, foi encaminhado ao hospital com queixa principal de dentes posicionados para a frente. Ao exame clínico o paciente apresentava má oclusão de Classe I de Angle e inclinação vestibular dos dentes anteriores. Havia sinais de queratose friccional na mucosa bucal. O plano de tratamento foi extrair os terceiros molares e distalizar todo o arco maxilar com mini-implantes por palatino. Bráquetes MBT 0,022 foram colados por vestibular. Fio de aço inoxidável 0,019 "x 0,025" foi colocado seqüencialmente. Mini-implantes foram instalados na região alveolar posterior da superfície palatina da maxila. A força de retração foi aplicada a partir de acessórios colados nas faces palatinas dos caninos superiores. O paciente foi reavaliado periodicamente. Os resultados da comparação pré-tratamento e pós-tratamento revelaram que todo o arco maxilar intruiu e transladou distalmente com rotação da mandíbula no sentido anti-horário com redução da AFAI. Houve uma ligeira redução na distância intercanina com expansão marginal nas regiões de pré-molar e molar. Foi percebida melhora no perfil facial sem sinal de reabsorção radicular. Assim, a região alveolar posterior pode ser considerada como um novo e apropriado local para instalação de mini-implante para promover movimento distal de toda a dentição maxilar. (AU)


Subject(s)
Humans , Male , Adult , Palate , Bone Screws , Orthodontic Anchorage Procedures
4.
Dental press j. orthod. (Impr.) ; 23(1): 46-55, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-891123

ABSTRACT

ABSTRACT Objective: This study aimed at evaluating whether changes in the insertion angle is a determining factor in the positioning of the miniscrews body in a region with larger interradicular space in the posterior maxilla. Methods: Analysis of 60 posterior maxillary quadrants were made using images obtained by means of cone-beam computed tomographic image (CBCT), with 0.076-mm voxel, which presented a real miniscrew inserted in the mesial region of the maxillary first molars, serving as reference point for the placement of the virtual miniscrews. Measurements of the distances between roots were made in three points on the body of the virtual miniscrews (A, B and C), at four different angulations, 70o, 60o, 50o and 40o (T1 to T4), in relation to the long axis of the second premolar. This evaluation was made in four groups, selected in accordance with the disposition of the roots of the second premolars and first molars: Group 1 (all types of roots), Group 2 (convergent roots), Group 3 (divergent roots) and Group 4 (parallel roots). Results: There were no statistically significant differences in the measurements of points A, B and C, at the different angles (70o, 60o, 50o and 40o) and in the different groups (p > 0.05). Conclusions: Changes in the insertion angle is not a determinant factor in the positioning of miniscrews body in regions with larger interradicular space in posterior maxilla.


RESUMO Objetivo: o presente estudo objetivou avaliar se alterações no ângulo de inserção do miniparafuso são um fator decisivo para a adaptação do corpo do parafuso em áreas com espaço inter-radicular aumentado, na região posterior da maxila. Métodos: foram realizadas análises em 60 quadrantes maxilares posteriores, a partir de imagens obtidas por tomografia computadorizada de feixe cônico (TCFC), com voxel de 0,076 mm, as quais apresentavam um miniparafuso real inserido na região mesial dos primeiros molares superiores, utilizado como ponto de referência para a inserção de miniparafusos virtuais. As distâncias inter-radiculares foram mensuradas utilizando-se três pontos marcados no corpo dos miniparafusos virtuais (A, B e C), inseridos com quatro angulações diferentes (70°, 60°, 50° e 40°) (T1 a T4) em relação ao longo eixo do segundo pré-molar. A avaliação foi realizada em quatro grupos, selecionados de acordo com a disposição das raízes dos segundos pré-molares e primeiros molares: Grupo 1 - contendo todos os tipos de raízes; Grupo 2 - raízes convergentes; Grupo 3 - raízes divergentes; e Grupo 4 - raízes paralelas. Resultados: não houve diferença estatisticamente significativa entre as medidas dos pontos A, B e C nas diferentes angulações (70°, 60°, 50° e 40°) ou entre os grupos (p > 0,05). Conclusões: alterações no ângulo de inserção dos miniparafusos não são um fator decisivo para a adaptação do corpo do parafuso, em áreas com espaço inter-radicular aumentado entre primeiro molar e segundo pré-molar superiores.


Subject(s)
Humans , Male , Female , Bone Screws , Orthodontic Anchorage Procedures/methods , Cone-Beam Computed Tomography , Orthodontic Appliances, Fixed , Maxilla/diagnostic imaging , Bicuspid/diagnostic imaging , Orthodontic Anchorage Procedures/instrumentation , Molar/diagnostic imaging
5.
Arq. bras. neurocir ; 36(2): 101-107, 30/06/2017.
Article in English | LILACS | ID: biblio-911174

ABSTRACT

In this article, we present the techniques of axis screw fixation (laminar, pars, pedicle and transarticular screws), discussing the indications and contraindications of each one, as well as surgical tips and anatomical landmarks.


No presente artigo, apresentamos as técnicas de fixação do áxis com parafusos (lamina, parafusos de pars, pedículo e transarticular), discutindos as indicações e contraindicações das mesmas, assim como dicas cirúrgicas e parâmetros anatômicos relevantes.


Subject(s)
Humans , Male , Female , Axis, Cervical Vertebra/surgery , Pedicle Screws
6.
Rev. bras. ortop ; 49(6): 671-674, Nov-Dec/2014. graf
Article in English | LILACS | ID: lil-732906

ABSTRACT

Arthroscopic reconstruction of the anterior cruciate ligament has been modernized through new surgical techniques and new materials. When tibial fixation is performed using an absorbable screw, complications may occur, such as formation of a pre-tibial cyst. The case described here is about a patient who presented an anteromedial synovial cyst in his right knee, three years after having undergone ACL reconstruction. The patient did not present any pain nor any complaints other than a mass that progressively increased in size, worsened after physical activities. Imaging examinations were requested: simple radiography of the knee and magnetic resonance. Anteromedial imaging of the knee showed a mass with well-delimited borders and internal fluid content, suggestive of a synovial cyst, with communication with the joint cavity through the tibial tunnel, without presenting enlargement or absorption of the bone tunnel. The cyst was surgically resected and the tibial tunnel occlusion was performed using a bone plug. The diagnosis of a synovial cyst was subsequently confirmed through the results from the anatomopathological examination. The patient presented good clinical evolution, with disappearance of the symptoms and a return to physical activities...


A reconstrução do ligamento cruzado anterior (LCA) por via artroscópica vem sendo modernizada por novas técnicas cirúrgicas e novos materiais. Quando feita a fixação tibial com parafuso absorvível podem ocorrer complicações, como a formação de um cisto pré-tibial. O caso em questão é de um paciente que apresentou um cisto sinovial anteromedial em joelho direito três anos após ter sido submetido a reconstrução do LCA. O paciente não apresentava dor ou outras queixas, apenas massa de aumento progressivo, com pioria após atividades físicas. Foram solicitados exames de imagem: radiografias simples do joelho que não apresentavam alterações; e ressonância magnética com imagem anteromedial em joelho sugestiva de cisto sinovial. Apresentava bordas bem delimitadas e conteúdo líquido interno, com comunicação com a cavidade articular através do túnel tibial, sem apresentar alargamento ou absorção do túnel ósseo. Foram feitas ressecção cirúrgica do cisto e oclusão do túnel tibial com tampão ósseo, com posterior confirmação do diagnóstico de cisto sinovial após resultado do exame anatomopatológico. O paciente apresentou boa evolução clínica, com desaparecimento dos sintomas e retorno às atividades físicas...


Subject(s)
Humans , Male , Middle Aged , Bone Screws , Anterior Cruciate Ligament/surgery , Postoperative Complications
7.
Full dent. sci ; 5(19): 454-461, jul. 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-726527

ABSTRACT

O tema seleção de pilares protéticos é, sem dúvida, um pré-requisito para o sucesso da reabilitação do paciente. Para se realizar um planejamento intelectual da seleção dos pilares protéticos ‚ fundamental conhecer as opções protéticas disponíveis e suas respectivas indicações e contraindicações. Entretanto, determinadas situações clínicas dificultam sua aplicação, devido ás limitações de certos componentes, …ás vezes estéticas, …ás vezes mecânicas. Com isso, vão sendo desenvolvidos novos componentes de acordo com as necessidades práticas, surgindo assim uma gama de pilares com o objetivo de facilitar a resolução de problemas clínicos. Este trabalho tem como finalidade demonstrar, através de um caso clínico, a importância do planejamento intelectual na seleção dos intermediários para se obter sucesso estético e mecânico em uma reabilitação metalocerâmica implantorretida parafusada com sistema tubo-parafuso, lateral ou transversal em implantes com inclinações vestibulares mantendo a reversibilidade


The selection of abutments is a requirement for a successful rehabilitation. To make an intellectual plan for the selection of prosthodontic abutment is extremely important to know the options available, as well as their indication and contraindication. However, some clinical situations may complicate its application, because of aesthetic or mechanical issues and other limitations of some components of the abutments. Therefore, new prosthodontics abutments are developed in order to meet practical needs and facilitate the solution of clinical issues. The present study aimed to present the importance of the intellectual plan for the selection of abutment in order to achieve aesthetic and mechanical success in a rehabilitation using metal ceramic screw retained implant, with lateral or transversal screw-tube system, in buccal angulation keeping the reversibility


Subject(s)
Humans , Esthetics, Dental , Dental Implants , Osseointegration/physiology , Prostheses and Implants , Dental Prosthesis, Implant-Supported/methods , Dental Abutments , Oral Surgical Procedures, Preprosthetic , Denture Design/methods
8.
ImplantNews ; 11(4): 444-450, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-730888

ABSTRACT

Objetivos: determinar se a quantidade da pré-carga influencia a resistência ao destorque do parafuso e pilar de duas peças com junção cone-morse indexada. Material e métodos: foram utilizados 60 análogos de implantes conexão tipo cone-morse de 11,5° com indexador hexagonal e 60 munhões universal cone-morse parafuso passante (4,5 mm de diâmetro, 2,5 mm de altura cinta de transmucoso e 4 mm de altura, não indexados), divididos em três grupos segundo o torque aplicado: 15 Ncm (G1); 20 Ncm (G2) e 25 Ncm (G3). A análise de variância fator único (Anova) e o teste LSD foram usados para as comparações entre os grupos (nível de significância 5%). Imagens em MEV foram realizadas na cabeça do parafuso e na chave de aplicação de torque. Resultados: os valores médios para os destorques dos parafusos foram: G1=17,48 Ncm, G2=21,16 Ncm e G3=26,42 Ncm, com diferencas estatisticamente significativas (p < 0,001) entre todos os grupos. Os valores médios para os destorques nos pilares foram: G1=15,17 Ncm, G2=19,58 Ncm e G3=21,64 Ncm, sendo (G1 e G2) e (G1 e G3) (p < 0,001); e G2 e G3 (p=0,02). Conclusão: 1) o aumento do torque no parafuso gerou valor médio aumentado do destorque em todos os grupos; 2) o aumento do torque gerou valor médio de destorque equivalente ao torque inicial dado para o G1 e G2, sendo este aumento menor no G3; 3) torques maiores do que os indicados pelo fabricante foram capazes de promover a deformação plástica na cabeça do parafuso após apertos repetidos


Objectives: to determine whether the applied preload influences on detorque resistance of abutment and abutment screw of a two-piece, indexed cone-morse taper connection. Material and methods: Sixty implant analogs (cone-morse taper=11,5 degrees) with internal hexagonal indexing and sixty cone morse universal abutments (4.5 mm diameter, 2.5 mm collar height, and 4 mm in height, non-indexed), were divided into three groups according to applied torques: 15 Ncm (G1); 20 Ncm (G2), and 25 Ncm (G3). The one-way Anova and LSD tests were used for comparisons among groups (at 5% level). Representative SEM images were obtained from screw heads and key drivers. Results: mean detorque abutment screw values were as follows: G1=17.48 Ncm, G2=21.16 Ncm, and G3=26.42 Ncm, with statistically significant differences (p < 0,001) among all tested groups. Also, the mean detorque abutment levels were: G1=15.17 Ncm, G2=19.58 Ncm, and G3=21.64 Ncm, being (G1 and G2); (G1 and G3) (p < 0.001); and G2 and G3 (p=0.02). Conclusion: 1) an increase on abutment screw torque level also increases detorque values for all groups; 2) an increase on abutment torque level provided detorque values proportional to that found in G1 and G2, being this lower for G3; 3) torque values higher than those preconized by the manufacturer lead to plastic deformation at screw heads after repeated tightening sequences


Subject(s)
Bone Screws , Dental Implantation
9.
Dent. press implantol ; 7(2): 39-48, Apr.-June 2013.
Article in Portuguese | LILACS, BBO | ID: lil-714110

ABSTRACT

Com o avanço das pesquisas relacionadas à osseointegração, a Implantodontia tornou-se um tratamento de prognóstico bastante satisfatório em Odontologia. Todavia, para se alcançar um sucesso mais duradouro no trabalho protético, é de suma importância a escolha adequada do tipo de retenção da prótese — se cimentada ou parafusada. O presente trabalho consiste em uma revisão de literatura sobre próteses cimentadas e parafusadas, tratando de suas vantagens e desvantagens, abordando quesitos como estética, passividade, reversibilidade, retenção e aspectos oclusais. A escolha entre prótese cimentada ou parafusada é de interesse do profissional, pois contribuirá para o sucesso em longo prazo do tratamento.


Due to the advancement of research related to osseointegration, Implantology has become a satisfactory prognostic treatmentin Dentistry. However, in order to achieve amore lasting success in prosthetic work, it is very important to choose the propertype ofretentionof the prosthesis, whether it iscemented or screwed. This workconsists of a literature review on the subject concerning cemented prosthesis as opposed to the screwed prosthesis, addressing their advantages and disadvantages, and issues such as aesthetics,passivity, reversibility, retention, andocclusal aspects. The choice between screwed or cemented prosthesis is of interest to the professional as it will contribute to the long term success of the treatment.


Subject(s)
Humans , Male , Female , Dental Prosthesis Design , Dental Prosthesis Retention , Biomechanical Phenomena , Brazil
10.
ImplantNews ; 9(6): 873-882, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850987

ABSTRACT

O objetivo deste estudo foi investigar a influência de um lubrificante líquido nos valores de torque/destorque de parafusos de pilar e cilindro protético em um sistema de hexágono externo; 20 implantes (3,75 mm x 13 mm) foram usados neste estudo. O longo eixo de cada implante foi colocado em anéis de PVC e fixado com resina acrílica incolor autopolimerizável. Na primeira etapa, pilares tipo Microscone foram apertados com 32 Ncm. Quatro grupos com cinco amostras cada foram utilizados: G1 (sem lubrificante, sem reaperto), G2 (sem lubrificante, com reaperto), G3 (com lubrificante, sem reaperto) e G4 (com lubrificante, com reaperto). Na segunda etapa, cilindros protéticos de Ti e Co-Cr foram apertados até 10 Ncm. Quatro grupos com cinco amostras cada foram utilizados: G1 (sem lubrificante, cilindro Ti), G2 (sem lubrificante, cilindro Co-Cr), G3 (com lubrificante, cilindro Ti) e G4 (com lubrificante, cilindro Co-Cr). O teste Anova dois critérios (nível de significância 5%) foi usado em ambas as etapas para comparar os valores entre os grupos. Os testes Kruskal-Wallis e Tukey foram usados para investigar o efeito dos reapertos nos valores finais de destorque em cada etapa. Os resultados mostraram que a interação entre lubrificante e reaperto não foi significativa na primeira etapa, mas diferenças foram vistas da segunda à quinta repetição de aperto na primeira etapa. Da mesma forma, não houve interação entre lubrificante e cilindro e os reapertos sequenciais não foram significativos na segunda etapa. Concluiu-se que o uso de um lubrificante pode aumentar o torque nos parafusos protéticos, mas não nos parafusos dos pilares.


The purpose of this study was to investigate the influence of a liquid lubricant on abutment and prosthetic screw torque/detorque values in an external hex system. Twenty dental implants (3.75 mm-diameter x 13 mm-length) were used in this study. The implant long axis was embedded into PVC rings and secured with clear autopolymerizing acrylic resin. In the first phase, Microscone-like abutments were tightened to 32 Ncm. Four groups of five samples each were made: G1 (no lubricant, no retightening), G2 (no lubricant, retightening), G3 (lubricant, no retightening), and G4 (lubricant, retightening). In the second phase, Ti and Co-Cr prosthetic cylinders were tightened to 10 Ncm. Four groups of five samples each were made: G1 (no lubricant, Ti cylinder), G2 (no lubricant, Co-Cr cylinder), G3 (lubricant, Ti cylinder) and G4 (lubricant, Co-Cr cylinder). Two-way Anova tests (5% significance level) were performed in both phases to compare values among groups. Also, the Kruskal-Wallis and Tukey tests were performed to investigate the effect of repeated tightening on final detorque values in each phase. Results demonstrated that the interaction between lubricant and retightening was not statistically significant for the first phase, but differences were identified between the 2nd and 5th tightening repetition. In the same way, interaction between lubricant and cylinder did not demonstrate significant results, and no differences were seen among repeated tightening in the second phase. It can be concluded that the use of a lubricant can increase torque on prosthetic but not abutment screws.


Subject(s)
Dental Implants , Torque , Biomechanical Phenomena
11.
Dental press j. orthod. (Impr.) ; 16(5): 119-126, set.-out. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-610769

ABSTRACT

INTRODUÇÃO: nos pacientes com fissura labiopalatina, observa-se, usualmente, uma severa atresia da maxila, especialmente na região anterior da arcada, cujo tratamento envolve expansão maxilar. OBJETIVO: o propósito desse estudo foi avaliar o padrão de expansão de três marcas de parafusos com limitador posterior na correção da deficiência transversa. MÉTODOS: foram realizadas 18 expansões em Typodont, com 6 simulações para cada grupo: G1 - parafuso Dentaurum®, G2 - parafuso Leone®, e G3 - parafuso Morelli®. Foram realizadas, para cada ensaio, 13 ativações de 2/4 de volta, totalizando 5,2mm de abertura do parafuso. Definiram-se os momentos das medições em inicial (T1), metade das ativações (T2) e final (T3). Com o auxílio de um paquímetro, foram medidas as seguintes distâncias: interprimeiros pré-molares (IP1), interssegundos pré-molares (IP2), intermolares (IM) e comprimento da arcada (CA). Os dados obtidos foram submetidos aos testes de Kolmogorov-Smirnov, de Tukey, de Friedman e ANOVA. RESULTADOS: observou-se que todos os grupos apresentaram um padrão de abertura em forma de "V" com maior expansão na região anterior da arcada, sendo mais expressivo no grupo G3 (29,58 por cento em IP1 e 9,73 por cento em IM). O aumento na medida CA foi semelhante para os grupos G1 e G3 (+12,65 por cento e +12,13 por cento, respectivamente), com menor valor para o G2 (+8,23 por cento). CONCLUSÕES: concluiu-se que todos os parafusos com limitador posterior utilizados nesse estudo podem ser empregados no tratamento da deficiência transversa da arcada. Entretanto, o parafuso Morelli® apresentou maior abertura na região anterior em relação à posterior, característica importante no tratamento de pacientes com fissura labiopalatina. Recomenda-se a realização de estudos clínicos para confirmação desses achados.


INTRODUCTION: Cleft lip and palate patients usually have severe maxillary deficiencies, particularly in the anterior region of this arch and their treatment should include maxillary expansion.OBJECTIVE: To evaluate the expansion pattern of three brands of fan-type expander screws to correct transverse deficiencies.METHODS: Eighteen expansions on typodonts were performed with 6 simulations for each group: G1 - Dentaurum® screw; G2 - Leone® screw; and G3 - Morelli® screw. For each trial 13 activations of 2/4 of a turn each were made with a 5.2 mm screw opening. Measurements were made at baseline (T1), after half of the activations (T2) and at the end of the trial (T3). A caliper was used to make the following measurements: Inter-first premolars (IP1), inter-second premolars (IP2) and intermolar (IM) widths and arch length (AL). The Kolmogorov-Smirnov, Tukey, Friedman and ANOVA tests were used to analyze data.RESULTS: All groups had a "V" shaped opening pattern and the greater expansion was found in the anterior region of the arch, which was more evident in the G3 (29.58% in IP1 and 9.73% in IM). The increase in AL was similar in G1 and G3 (+12.65% and +12.13%) and the lowest value was found in G2 (+8.23%).CONCLUSIONS: All the fan-type expander screws used in this study may be used to treat dental arch transverse deficiencies. However, the use of the Morelli screw resulted in a greater opening in the anterior region than in the posterior region, an important characteristic in the treatment of cleft lip and palate patients. Further clinical studies should be conducted to confirm these findings.


Subject(s)
Bone Nails , Cleft Lip , Cleft Palate , Palatal Expansion Technique , Dental Arch/abnormalities , Lip/abnormalities , Materials Testing , Palate/abnormalities
12.
ImplantNews ; 8(6): 855-858, 2011. tab
Article in Portuguese | LILACS, BBO | ID: lil-642524

ABSTRACT

O objetivo deste artigo foi relacionar as fraturas de coroas ou falhas de parafusos protéticos (fratura e/ou afrouxamento) de próteses sobreimplantes com parâmetros clínicos. Foram avaliados 43 pacientes - portadores de 213 implantes osseointegrados em função - que apresentaram algum tipo de falha protética funcional. Foram formados dois grupos: G1 - fratura de coroa protética; G2 - falha do parafuso protético (fratura e/ou afrouxamento). Os fatores analisados incluíram localização, tempo de prótese em função, fase protética, tipo de prótese, tipo de pilar e material de revestimento estético. Observaram-se 46 fraturas de coroa protética e 51 falhas de parafuso. Houve diferença estatística quanto à localização, tipo de prótese e material de revestimento estético entre os grupos 1 e 2 (p < 0,05). Concluiu-se que as fraturas de coroa protética estão relacionadas às próteses totais confeccionadas em acrílico localizadas na região superior e anterior. Falhas do parafuso protético estão relacionadas às próteses unitárias confeccionadas em cerâmica localizadas na região inferior e posterior.


The aim of this paper is to relate the incidence of crown fractures or prosthetic screw failures (fracture and/or loosening) with clinical parameters. Forty-three patients (213 implants) that presented some kind of prosthetic functional failure were evaluated. The study was divided into two groups: G1 - fracture of the prosthetic crown and G2 - failure of the prosthetic screw (fracture and/or loosening). The parameters analyzed included implant positioning, time, prosthetic phase, prosthesis type, abutment, and the veneering material. Forty-six fractures of the prosthetic crown and 51 screw failures were reported. There was statistical difference regarding positioning, prosthesis, and veneering material between groups 1 and 2 (p < 0.05). It can be concluded that fractures of the prosthetic crown are related to full dentures made with acrylic teeth and positioned in the anterior site of the upper jaw. Meanwhile, the prosthetic screw failures are related to ceramic single crowns positioned in the posterior site of the lower jaw.


Subject(s)
Humans , Dental Implants , Dental Restoration Failure , Laboratories, Dental , Prostheses and Implants
13.
Acta ortop. bras ; 19(1): 28-31, 2011. ilus
Article in Portuguese | LILACS | ID: lil-582362

ABSTRACT

OBJETIVO: Apresentar um novo sistema de acoplamento solidário entre chave e parafuso de interferência, assim como ensaios biomecânicos que avaliem a segurança de sua utilização. MÉTODOS: O novo sistema foi submetido a ensaios biomecânicos de torção. Foram realizados dois tipos de análise: torque máximo de inserção manual dos parafusos em osso bovino; ensaios destrutivos de torção do sistema em máquina INSTRON 55MT. Os mesmos testes foram realizados em um grupo controle utilizando um sistema de acoplamento já disponível no mercado. (Acufex®) RESULTADOS: Nos ensaios de inserção em fêmures bovinos as médias de valores aferidos com torquímetro digital foram 1,958 N/m para Acufex® e 2,563 N/m para FMRP. Considerando p<0,05, não houve diferença significativa (p=0,02) nos valores de torque máximo de inserção nos dois sistemas estudados. Os valores médios de torque máximo para deformar o parafuso foram de 15 N/m para o parafuso Acufex® e 13 N/m para o parafuso FMRP, portanto, sem diferença estatística (p>0,05). Ao avaliar a deformação angular, não houve diferença significativa entre os grupos de parafuso (p=0,15). CONCLUSÃO: O novo sistema de acoplamento para parafusos de interferência desenvolvido na FMRP-USP revelou resistência à torção comparável a sistema já disponível no mercado e regulamentado para uso internacional.


OBJECTIVE: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. METHODS: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex®). RESULTS: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex® and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex® screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). CONCLUSION: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.


Subject(s)
Animals , Cattle , Anterior Cruciate Ligament , Bone Screws , Anterior Cruciate Ligament/surgery , Biomechanical Phenomena , Equipment Safety , Femur , Knee/surgery , Orthopedic Equipment
14.
Araçatuba; s.n; 2011. 155 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-710786

ABSTRACT

Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...


Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...


Subject(s)
Dental Implantation , Dental Prosthesis, Implant-Supported , Post and Core Technique
15.
Araçatuba; s.n; 2011. 155 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-705168

ABSTRACT

Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...


Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...


Subject(s)
Dental Implantation , Dental Prosthesis, Implant-Supported , Post and Core Technique
16.
Bauru; s.n; 2011. 100 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-865841

ABSTRACT

Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão...


Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.


Subject(s)
Bone Screws , Crowns , Cementation/methods , Dental Implants , Surface Properties , Tensile Strength , Torque
17.
ImplantNews ; 7(3): 309-314, 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-563034

ABSTRACT

A reposição das perdas dentárias, antes limitadas ao uso de próteses convencionais, atualmente, podem ser feitas por próteses implantossuportadas. Com a aplicação dos conceitos de planejamento reverso, é possível obter resultados protéticos satisfatórios, tendo uma previsão dos insucessos que podem ocorrer durante o tratamento. Assim, através de um caso clínico, o presente artigo tem como objetivo demonstrar a associação de duas técnicas de retenção de prótese implantossuportada, associada ao planejamento reverso, para a resolução de um caso de falha estética e funcional do conjunto implante-prótese. Paciente do sexo feminino, 63 anos, portando no arco superior uma prótese do tipo protocolo e no arco inferior uma prótese parcial removível Classe I, modificação 2 de Kennedy. A queixa principal da paciente era o constante mau cheiro e a estética precária de ambas as próteses. O plano de tratamento estabelecido foi a confecção de duas próteses tipo protocolo, sendo a inferior imediata e a superior uma associação de prótese cimentada e parafusada. Após a resolução do plano de tratamento, todos os anseios da paciente foram alcançados, recuperando estética, função e sorriso.


In the past, treatment of tooth loss was limited to the use of conventional total prostheses. Nowadays, the use of implant-supported prostheses has brought new horizons. It is possible to provide satisfactory esthetic results according to a reverse planning philosophy. Through a clinical case, the present article aims to demonstrate the association of two retention techniques for the resolution of aesthetic and functional drawbacks in both maxillary arches. A female 63 years-old patient presented with her maxillary total implant-supported prosthesis and mandibular conventional removable prosthesis (Kennedy´s Class I, modification 2). Her main complaints were oral malodor and unacceptable aesthetics. For this, screw-cemented (hybrid) and immediate prostheses were provided in the maxillary and mandibular arches. Thus, esthetics, function, and smile were improved to achieve all patient´s desires.


Subject(s)
Humans , Female , Adult , Dental Implants , Dental Prosthesis, Implant-Supported , Mouth Rehabilitation
18.
RBM rev. bras. med ; 66(1,n.esp)dez. 2009.
Article in Portuguese | LILACS | ID: lil-549533

ABSTRACT

Objetivo: Avaliar o resultado clínico da estabilização dinâmica com o dispositivo Dynesis em pacientes com dor lombar e alteração degenerativa do disco intervertebral. Método: Os autores avaliaram 24 pacientes, com idade média de 43,2anos (26 a 57 anos) com queixa de dor lombar com no mínimo seis meses de tratamento conservador sem melhora e ressonância magnética com alteração degenerativa discal avaliado pela classificação de Pffirmann e preservação da altura do disco de pelo menos 40% na radiografia no plano sagital. Foi realizada a fixação com parafuso dinâmico (Dynesis). A avaliação foi realizada por meio da escala visual análoga para dor. Resultado: A escala visual análoga da dor pré-operatoriamente obteve média de 7,4 pontos e após seis meses caiu para 2,9 pontos de média. Conclusão: Neste estudo concluímos que há uma melhora da dor lombar após estabilização dinâmica com dispositivo Dynesis.

19.
Full dent. sci ; 1(1): 48-57, 2009.
Article in Portuguese | LILACS, BBO | ID: lil-602569

ABSTRACT

Este estudo foi realizado com o objetivo de determinar o torque de montagem que inicia o processo de deformação plástica dos parafusos de fixação do intermediário em implantes, com a conexão do tipo hexágono externo. Foram analisados as diferenças de torque no sistema hexágono externo, com o carregamento de pré-carga e pré-carga mais carregamento oclusal, considerando os fatores de tolerância, H4 ou H6 para a rosca interna dos implantes e para a rosca dos parafusos diante do parafuso de titânio grau 4. Neste trabalho foram definidos para estudo os implantes disponíveis pela empresa DSP (Dental Special Products) Biomedical - hexágono externo (HE) fixação, com margem de segurança, sem sofrer as deformações plásticas pertinentes ao material. Dessa forma, tomaram-se para a realização das análises, os parafusos com 2mm de diâmetro nominal de cada sistema. O diâmetro do parafuso escolhido determinou os demais componentes do sistema. Os resultados da pesquisa evidenciaram que em todas as análises, o estado de tensões do parafuso H4 (ajuste apertado) é menor do que no H6 (ajuste folgado). Pode-se inferir que uma junta aparafusada com ajuste H4 é melhor que a H6 apesar de serem similares.As análises do sistema hexágono externo mostraram que, com o torque de pré-carga no valor e 32 N.cm, e os carregamentos de oclusão em 100, 30 e 30N.cm ocorreu uma plastificação no parafuso de carga oclusal, produzindo uma deformação plástica nos primeiros filetes da rosca do parafuso, possibilitando a soltura e até a ruptura dos mesmos.


This study was carried out to determine the mounting torque that starts the process of plastic deformation of intermediate fixation screws in implants, with external Hexagon type connection. Were analyzed torque differences in external Hexagon system with load preload and plus occlusal loading, considering the factors of tolerance, H4 or H6 for internal screw and implants for thread screws titanium screw face of grade 4. this work have been defined for study available by biomedical implant company - Dental Special Products (DSP) - Hexagon external (Ho) attachment, with a safety margin, without undergoing the relevant material plastic deformations. Thus made for carrying out analyses, the screws with 2 mm nominal diameter of each system. The diameter of the screw chosen determined the other system components. The results of the survey revealed that in all the analyses, the State of tension adjustment screw H4 (tight) is less than generous budget adjustment in H6. It can be inferred that a joint screwed with adjustment H4 is better than H6 are similar. The external Hexagon system analyses showed that with the torque on 32N.cm and 100 occlusion uploads, 30 and 30N cm plastic wrap occurred in oclusal load screw, producing a plastic deformation in the first thread fillets, enabling the screw and even rupture loosening.


Subject(s)
Finite Element Analysis , Biomechanical Phenomena , Dental Implants , Prostheses and Implants
20.
Acta ortop. bras ; 17(4): 207-210, 2009. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-525648

ABSTRACT

INTRODUÇÃO: A fotoelasticidade é utilizada para avaliar as tensões/deformações produzidas nos materiais fotoelásticos, quando submetidos a determinado carregamento, através da observação de efeitos óticos. O desempenho do parafuso e as funções mecânicas estão diretamente relacionados com a qualidade da fixação dos parafusos nas vértebras. A fotoelasticidade é uma ferramenta importante para realizar estudos comparativos desta natureza. OBJETIVO: O objetivo deste estudo foi comparar por meio da fotoelasticidade, as tensões internas produzidas pelo parafuso com 6 mm de diâmetro externo, quando submetido a duas diferentes forças de arrancamento. MATERIAIS E MÉTODOS: Para isso, foram confeccionados quatro modelos fotoelásticos. A simulação foi realizada utilizando duas forças de arrancamento 0,75 e 1,50 kgf. As tensões cisalhantes foram calculadas nos 19 pontos em torno dos parafusos, utilizando o método de compensação de Tardy. RESULTADOS: Os valores das tensões cisalhantes foram maiores quando utilizada a força de arrancamento de 1,50 kgf. CONCLUSÃO: Assim sendo, o parafuso estará mais suscetível ao arrancamento com a aplicação de força de maior intensidade. De acordo com as análises realizadas verificamos também que o local de maior tensão cisalhante foi observado no pico das cristas, principalmente próxima às pontas dos parafusos, independente da força utilizada.


INTRODUCTION: The photoelasticity is used for assessing the tensions/deformations involved in photoelastic materials when submitted to a given load by the observation of optical effects. The screw performance and mechanical functions are directly associated to the quality of the screws fixation in the vertebrae. Photoelasticity is an important tool to perform comparative studies of this nature OBJECTIVE: The aim of this study was to compare, by using photoelasticity, internal stresses produced by the screw with an external diameter of 6 mm, when submitted to two different pullout strengths. MATERIALS AND METHODS: For this, four photoelastic models were produced. The simulation was conducted by using two pullout strengths: 0.75 and 1.50 kgf. The maximum shear stresses were calculated on 19 points around the screws, using the Tardy compensation method. RESULTS: The values of maximum shear stress were higher with the load of 1.50 kgf. CONCLUSION: Thus, the screw will be more susceptible to pullout when heavier loads are applied. According to our analysis, we also found that the site with the highest maximum shear stress was found to be at the peak of creast, particularly near the tips of the screws, regardless of the load employed.


Subject(s)
Bone Screws , Epoxy Resins , Materials Testing , Orthopedic Fixation Devices , Resins , Shear Strength , Stainless Steel , Biomechanical Phenomena , Elasticity , Evaluation Studies as Topic , Evaluation Studies as Topic , Tensile Strength